Online UPS 10KVA 15KVA 20KVA three phase low frequency industrial UPS for medical application

FOB Reference Price:Get Latest Price
$555.00 - $6,795.00 / Pieces | 5 Piece/Pieces Sample order will be discussed (Min. Order)
Report Suspicious Activity
Overview
Quick Details
Place of Origin:
Guangdong, China
Brand Name:
CPSY
Model Number:
GP3310K/GP3315K/GP3320K/GP3330K/GP3340K
Phase:
Three Phase
Protection:
Unbalanced Loads
Weight:
118-840KGS
Output Voltage:
380V
Type:
On-line
Application:
Industrial
Product name:
Uninterrupted Power System
Online double-conversion:
Yes
ISO-transformer:
Yes
Battery Type:
Sealed Lead Acid Battery
Wave Form:
Pure Sinewave
Display:
LCD Display
Color:
Black
Transfer Time:
0ms
Low Frequency:
Yes
Full protection:
Yes
Supply Ability
Supply Ability:
1000 Piece/Pieces per Week We can expand our production if needed
Packaging & Delivery
Packaging Details
1pcs in one carton, one carton in one pallet
Port
Shenzhen
Lead Time :
15-20days after receiving the deposit
Product Description

Online UPS 10KVA 15KVA 20KVA three phase low frequency industrial UPS for medical application

 

Main Features

 

Online double-conversion

DSP technology guarantees high reliability

True galvanic isolation transformer design

Control designed to withstand all kinds of loads

Intelligent battery management to prolong battery lifecycle

Independent ventilation enhance durable operation under harsh environment

Adjustable battery numbers

Accept dual-mains input

Parallel operation with up to 4 units(option)

Variety if communication options available

Optional 7″ touch LCD

Reverse phase frequency operation and supports non-neutral input

 

Technical Specification

 

ModelGP3310KGP3315KGP3320KGP3330KGP3340KGP3360KGP3380KGP33100KGP33120K
CAPACITY

10KVA/

8KW

15KVA/

12KW

20KVA/

16KW

30KVA/

24KW

40KVA/

32KW

60KVA/

48KW

80KVA/

64KW

100KVA/

80KW

120KVA/

96KW

INPUT
Nominal Voltage3 X 380VAC/400VAC(3Ph + N)
Acceptable Voltage Range285VAC-475VAC
Frequency50/60Hz ±10%
INVERTER
Nominal Voltage3 X 380VAC/400VAC(3Ph + N)
PrecisionStationary, ±1%; Transitory, ±5%(load variations 100-0-100%)
Frequency50/60Hz synchronised ±1% with mains absent ±0.1 Hz
Max.Synchronisation Speed±  1Hz/s
WaveformPure Sine Wave
Total Harmonic Distortion(THDv)<2%(Linear load); <5%(Non-linear load)
Phase Displacement120℃ ±1%(balanced load); 120℃ ±2%(imbalanced 50% of the load)
Dynamic Recovery Time3 cycles at 90% of the static value
Admissible Overload110% for 10min; 150% for 60sec; >160% for 200ms
Admissible Crest Factor1/3
Admissible Power Factor0.6-1(inductive or capactive)
Imbalance Output Voltage @ 100% Unbalanced Load<1%
Current LimitHigh overload, short-circuit, RMS Voltage Limit, High crest-factor current, peak voltage limit
STATIC BYPASS
TypeSolid state
Voltage3 x 380VAC/400VAC(3Ph + N)
Frequency50/60Hz
Activation CriterionMicroprocessor control
Transfer TimeZero
Admissible Overload150% for 1 hour; 180% for 30sec; >200% for 200ms
Transfer to BypassImmedate, for overloads above 160%
Retransfer Automatic
MANAGEMENT BYPASS         
TypeWithout interruption         
Voltage      3 x 400v (3Ph + N)   
Frequency50/60Hz         
Overall Efficiency(Line Mode)         
Line Mode 89%  90% 91% 92%
Battery Mode   90%   91%  92%   93%
BATTERY & CHARGER         
Battery Type and Numbers         12VDC X 32pcs(29-32pcs adjustable)
Nominal Battery Voltage     384VDC(Based on 32pcs batteries)    
Charging MethodCC/CV         
Charging CurrentDefault 10A, Max.=Capacity(kw)/Battery Voltage(real-time)  Default, 10A. Max.40A; 5A@full load      
Charging Voltage432 VDC (Based on 32pcs batteries)        
PHYSICAL         
Dimension, D X W X H(mm)656 x 405 x 817   656 x405 x 941  821 x 432 x 1159  975 x 554 x 1286 975 x 554 x1326
Net Weight(kgs)   118120145 193  278365  471573 650

 

Product Images

 

 

 

Company Information

 Factory Images and what certifications do we have?

 

Applications

 

 

FAQ

 

What is a UPS? 
An uninterruptible power supply, also uninterruptible power source, UPS or battery/flywheel backup, is an electrical apparatus that provides emergency power to a load when the input power source, typically the utility main, fails. 
  
Why do I need a UPS? 
Power disturbances and blackouts can be costly.  Preserving Information, the availability of equipment critical to the business, maintaining fully occupied staff, reduction of cost over-runs, performing reliably and getting results on time are all key elements in any successful operation.   A UPS will provide clean, stable power to critical application equipment throughout utility power disturbances and power failure. 
  
How many types of UPS are there? 
There are three typical types of UPS: OFF-LINE, ON-LINE, and LINE INTERACTIVE. 
  
What is an " ON LINE UPS ?" 
An Online UPS takes incoming power, converts it to DC, conditions it, and converts it back to AC. This means the UPS is Online since there is no delay to switch to battery. Use an online UPS for your critical applications, high availability servers, etc. The output of these online UPS systems are TRUE sine wave, and is usually better than power from the electric company. 
  
What is a "LINE INTERACTIVE UPS ?" 
An Online UPS takes incoming power, converts it to DC, conditions it, and converts it back to AC. This means the UPS is Online since there is no delay to switch to battery. Use an online UPS for your critical applications, high availability servers, etc. The output of these online UPS systems are TRUE sine wave, and is usually better than power from the electric company. 
 

How to choose the right UPS? 
1. Understand specifications of all UPS.
2. Consider the requirements of power quality.
3. Understand the current capacity of UPS and consider the future expansion.
4. Choose reputed brands and manufacturers.
5. Choose UPS based on your requirements. 

 

 

Contact Us

 